Repair of slurry pipeline

Pipework at an installation was experiencing severe corrosion issues caused by abrasive limestone slurry material. Due to the extent of the damage, the average lifetime of the pipes had been dramatically reduced to less than six months before the pipe spool pieces had to be completely replaced. The facility required a repair solution that would provide extremely robust protection against the abrasive material and therefore significantly increase the working life of the equipment.

The pipes are situated in the FGD (Flue Gas Desulphurisation) plant part of a power station; a direct product of this process is that calcium sulphate (CaSO3) and carbon dioxide (CO2) are created. The limestone slurry, now containing highly abrasive limestone material and corrosive calcium sulphate is then pumped away for further treatment. It is at this step, where the pipework is subjected to the highly erosive and corrosive media.

Belzona polymeric materials had already been used for the same client, resulting in a 50% increase in the usable life of the pipework, so the same repair system and application was specified.

Belzona 1812 (Ceramic Carbide) was chosen to repair and protect the existing pipework, consisting of 12 pipe spools. This composite material combines extremely hard, closely packed abrasion resistant ceramic aggregates in a polymeric binder, making it ideal for the maintenance of substrates damaged by particle abrasion. This durable technology fortifies the 4” pipe interiors, ensuring they remain protected when subjected to the abrasive limestone slurry.

Firstly, the substrate was grit blasted to remove all possible contaminants and also to achieve Surface Cleanliness Standard Sa2½ with a 75μ profile. Following this, the pipes were then salt tested to confirm acceptable levels of contamination.

To reduce the application time and to increase accuracy, a flanged mould with a machined insert was manufactured. This mould was then bolted onto the pipes prior to coating, allowing the technician to completely fill all spaces with Belzona 1812 uniformly whilst ensuring the internal dimensions were kept to specification. Finally, the pipes were machined true using a diamond tipped tool.

“Due to its molecular structure making it extremely resistant to erosion and corrosion, the Belzona material was able to not only repair the damaged equipment, but also significantly increase its life expectancy too. This will save the power station a considerable amount of financial expenditure as they will no longer require the excessive amount of downtime needed for the removal and replacement of the pipework,” explained Steve Smith, Quotation Engineer, Pump Supply & Repair Group.